inventory

Strong marketing of inventory, fully integrated

KGVP130 GENSET

RATING GUIDELINES
PRIME POWER rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A10 % overload capability for govering purpose is available for this rating.
MAXIMUM STANDBY POWER rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36

  • There are no features available

Engine Make & Model
Origin
Alternator Type
Control Panel
Circuit Breaker Type
Tropical Cooling System
Electrical Governor
Electrical Stop Solenoid, Energized to Run
Emission Controlled
No. of Cylinders / Alignment
Cycle
Aspiration
Injection
Bore, mm
Stroke, mm
Displacement,I
Compression Ratio
Starting
Alternators, Amps
Prime Power
104KWe / 130KVA
106KWe / 132KVA
Volvo Penta TAD532GE
GERMANY
Stamford UCI274E
Deap Sea - 6110
3 Pole MCCB
55°C
4 In Line
4 Stroke
Turbocharged
Electronic
108
130
4.76
17.5:1
12V Electric
12V/55A
Standby Power
114KWe / 142KVA
117KWe / 146KVA
Genset Specifications
Engine Technical Data
No. of Bearings
Insulation System
Excitation
Voltage Regulator
Protection
Temperature Rise,°C
Regulation
No. of Phases
No. of Poles
Single Bearing
Class H
Self Excited
SX460
IP23
125
±1.0%
3
4
Alternator Technical Data
KGVP130 GENSET
Image for illustration purposes only
International Standards
Engine confirm to ISO 9001: 2000, ISO 14001, ISO10054, ISO 3046,BS 5514,DIN 6271.
Alternator confirm to ISO 9001, ISO 14001, BS EN 60034, BS 5000, VDE 0530, NEMA MG1-32, IEC34 CSA C22.2-100, AS 1359, BS 6861 1, B En 61000-6-2:2001
RATING GUIDELINES
PRIME POWER rating corresponds to ISO Standard Power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A10 % overload capability for govering purpose is available for this rating.
MAXIMUM STANDBY POWER rating corresponds to ISO Standard Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks in the event of normal utility power failure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36
1500rpm, 50 Hz
1800rpm, 60Hz
14.33
15.33
21.18
22.38
28.79
30.39
Fuel System
50%
75%
100%
*Prime Power (l/hr)
Height(m)
1.52
Width(m)
0.90
Length(m)
2.35
Weight(kg)
1280
Tank Capacity(L)
125
Dimensions & Weights
Output

Make: VOLVO Penta
Model: Generator
Back to top